-8%

CMP-1006 Digital Clamp-on multimeter

Availability:

5 in stock


 

Additionally:

  • safe, insulated measuring clamps,
  • autoranging/manual range selection,
  • DATA HOLD function, for holding measured values,
  • backlit LCD,
  • DC ZERO mode of measurement for DC current, possibility to zero the display and reading relative actual value less stored zero value,
  • MAX/MIN function,
  • over range indication,
  • AUTO-OFF function.

31,587 34,221

5 in stock

Compare

(TRUE RMS) up to 1000 A.

Measurement of INRUSH current in start-up phase of electrical device (high frequency of sampling)

AC/DC voltage measurement (TRUE RMS) up to 600 V.

Resistance measurement and continuity test:

  • continuity test with acoustic signalling (beeper) for resistance below 40.

Temperature measurement (Fahrenheit and Celsius units).

Frequency measurement.

Duty cycle measurement.

Diode test.

Category:
Weight 0.3 kg
Dimensions 23 × 8 × 5 cm

Electric security:

  • measurement category: CAT III 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

 

Other technical data:

  • power supply: 9 V battery type 6LR61
  • display: 6600 counts, backlit LCD
  • continuity test: threshold 40 Ω; test current < 0,5 mA
  • diode test: test current of 0,3 mA, typical open circuit voltage < 3 V DC, typical
  • low battery indication: BAT displayed
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • INRUSH: integration time 100 ms
  • temperature sensor: type K thermocouple
  • input impedance: 10 MΩ (V DC and V AC)
  • AC bandwidth: 50…400 Hz (A AC and V AC)
  • auto power OFF: approx. 25 min.
  • dimensions: 229 x 80 x 49 mm
  • weight: 303 g
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
  • quality standard: ISO 9001

 

Rated operational conditions:

  • internal clamp diameters: d1 = 36 mm/d2 = 52 mm
  • operating temperature: +5…+40°C
  • storage temperature: -20…+60°C
  • operating humidity: max 80% up to 31°C decreasing linearly to 50% at 40°C
  • storage humidity: <80%
  • operating altitude: max 2000 m

 

AC/DC current measurement (TRUE RMS)

Range Resolution Accuracy (DC) Accuracy (AC)
0…659,9 A 0,1 A ±(2,5% m.v. +5 dgt) ±(2,5% m.v + 8 dgt) for f = 50…60 Hz
660…1000 A 1 A ±(2,8% m.v. +8 dgt) ±(2,8% m.v. + 8 dgt) for f = 50…60 Hz

 

DC voltage measurement

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,5% m.v. + 3 dgt)
6,60…65,99 V 0,01 V ±(1,5% m.v. + 3 dgt)
66,0…600,0 V 0,1 V ±(1,5% m.v. + 3 dgt)

 

AC voltage measurement (TRUE RMS)

Range Resolution Accuracy
0…6,599 V 0,001 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
6,60…65,99 V 0,01 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz
66,0…600,0 V 0,1 V ±(1,8% m.v. + 5 dgt) for f = 50…60 Hz

 

Resistance measurement

Range Resolution Accuracy
0,0…659,9 Ω 0,1 Ω ±(1,0% m.v. + 4 dgt)
0,660…6,599 kΩ 0,001 kΩ ±(1,5% m.v. + 2 dgt)
6,60…65,99 kΩ 0,01 kΩ ±(1,5% m.v. + 2 dgt)
66,0…659,9 kΩ 0,1 kΩ ±(1,5% m.v. + 2 dgt)
0,660…6,599 MΩ 0,001 MΩ ±(2,5% m.v. + 3 dgt)
6,60…66,00 MΩ 0,01 MΩ ±(3,5% m.v. + 5 dgt)

 

Frequency measurement

Range Resolution Accuracy
30,0…999,9 Hz 0,1 Hz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
1,000…9,999 kHz 0,001 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle
10,00…15,00 kHz 0,01 kHz ±(1.2% m.v. + 2 dgt) sensitivity:30…5 kHz:10 Vrms min. 5 kHz…15 kHz:40 Vrms min. for 20%…80% duty cycle

 

Temperature measurement

Range Resolution Accuracy
-20…760°C 0,1°C ±(3,0% m.v. + 5°C)
-4…1400°F 0,1°F ±(3,0% m.v. + 9°F)

 

Duty cycle measurement

Range Resolution Accuracy
10,0…94,9% 0,1% ±(1,2% m.v. + 2 dgt)
  • pulse width: 100μs…100 ms,
  • frequency range: 30 Hz…5 kHz,
  • sensitivity: 30 Hz…5 kHz: 10 Vrms, 5 kHz…15 kHz: 40 Vrms.

 

„m.v.”- measured value

 

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMP-1006 Digital Clamp-on multimeter”

There are no reviews yet.

  • UT230B-EU Power Socket

    0 out of 5
    (0)
    SKU: n/a
  • UT681HDMI Cable Tester

    0 out of 5
    (0)

    1. Tests HDMI/MINI-HDMI cables

    2. Fastline collocation type: A with A, A with C and C with C

    3. Checks circuit breakage, short circuit, cross circuit and the missing wire

    4. 20 visible LED indicators

    5. Can toggle between scan and full display test modes

    6. Single key operation

    7. Manual/auto power off (after 10-minute inactivity)

    8. Low battery indication

    9. CE certification

    10. Power supplied by 9V layer-built battery

    SKU: n/a
  • MECHANIC Industrial Triocular stereo microscope MC75T-B3

    0 out of 5
    (0)

    Binocluar magnification(7X-45X/2.1X-180X)

    Eyepiece(WF10X/20MM,WF20X/10MM)

    Objectlens(10.6X-5.5X),

    Aux(0.3X/287,0.5X/165,0.7X/120,1.5X/45,2X/30)

    Continuourszoom(0.7X-4.5X)

    SKU: n/a