-7%

YIHUA 605D DC Power Supply


YH-605D communication maintenance power supply

605D communication maintenance power supply is a single line output of stabilized high accuracy

DC stabilized power supply. The output voltage and current can be adjusted continuously within

the rated range. Double digital display shows output voltage and current independently. Several

protection functions include current limitation, voltage reduction, short circuit protection, over-

temperature protection, etc.

The design is applied to production line of the plant, maintenance, laboratories and is also

a necessary device for the communication industry.

22,000 23,710

Compare

Principle description of constant voltage/constant current CV/CC

 

The operation mode of constant voltage/constant current can be automatically switched depending

on the comparison result of the load current and limited current value.

  1. a) Constant voltage CV

When the existing current value is smaller than the set output limit current value, the power supply

is working under the constant voltage mode. The CV indicator light on the front panel is on, the output

voltage is controlled and it will be the same as the set value. Current changes with the load.

  1. b) Constant current mode (CC)

When the current value exceeds the limit value of the output current, the equipment will work in the

 CC mode. The CC indicator light on the front panel is on, the output current value is controlled to

the set value. Since the limited output power cannot be overloaded, the output voltage can be lower

 than the set value. When the output current is lower than the set value, the equipment will

automatically change to CC mode.

Category:
Weight 5.9 kg
Dimensions 25 × 13 × 15 cm

Product parameters

Machine parameters
rated voltage AC220V  50Hz
Power of complete machine 380W
Operating environment 0~40℃  relative humidity <80%
Storage Temperature -20~80℃  relative humidity <80%
Dimensions 255*130*150mm
weight 6.1KG
Specifications
output voltage Adjustable continuously within 0~60V
output current Adjustable continuously within 0~5A

(current limitation adjustment when above 0.2A)

output power 300W
Source effect 1mV
load effect ≤0.33%
Ripple noise ≤3mVrms(5Hz ~ 1MHz)/≤3mArms
Display accuracy 0.1V/0.1A/1mA
Protection mode Over-current, short circuit, over-temperature protection
Dissipation mode air cooling

Brand

YIHUA

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “YIHUA 605D DC Power Supply”

There are no reviews yet.

  • Clamp Meter DT 3266

    (1)
    • clamp multimeter
    • Performs AC/DC Voltage, AC current, Resistance, Audible Continuity, Diode
    • Temperature Measurements, and non-contact ACV Detect (NCV) as well as Capacitance, Hz, etc.
    • Auto Ranging DMM with AC current clamp meter function
    SKU: n/a
  • UT-CS09D Flex Clamp Sensor

    0 out of 5
    (0)

    Features of UT-CS09D Flex Clamp Sensor

    Certificates: CE, UKCA, cETLus

    ● Flex clamp can measure from 1.5A to 3000A current

    ● 1m drop proof
    ● Robust terminal connection
    ● Directly displays current when connected to UT206B/208B
    SKU: n/a
  • LM120C Laser Distance Meters (Discontinued)

    0 out of 5
    (0)

    Features of LM80C/LM120C/LM200C Laser Distance Meters

    ● 2.4-inch color screen

    ● 12 measurement modes
    ● Electronic leveling
    ● 3 selectable measurement references
    ● USB 3.0 supply power
    ● 100 groups of data storage
    ● Rotatable screen
    ● Camera-aided measurement
    ● 2m drop test
    ● IP65 dust and water proof
    SKU: n/a
  • MRU-30 Earth Resistance and Resistivity Meter

    0 out of 5
    (0)

     

    • It allows to take the measurements of:

      • earthing resistance using auxiliary electrodes,
      • earthing resistance using auxiliary electrodes and clamp (for measurements of multiple earthing),
      • earthing resistance using double clamps for measuring multiple earthing without underground connections.
      • ground resistivity (Wenner method),
      • continuity of equipotential bondings and protective
      • conductors (meeting the requirements IEC 60364) with auto-zero function – with current 200mA.

      Additionally:

      • measurement of resistance of auxiliary electrodes RS and RH,
      • measurement of interference voltage,
      • measurement in the presence of interference voltage in the power network
      • with frequency 50Hz, 60Hz,
      • selection of maximum measuring voltage (25V and 50V),
      • introducing the distance between the electrodes for the resistivity in metres (m) and feet (ft),
      • memory of 990 measurements (10 banks of 99 cells each),
      • calibration of clamp used,
      • data transmission to the computer (USB),
      • indication of battery state.
    SKU: n/a