-18%

CMM-10 Multimeter

Availability:

5 in stock


  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).

11,844 14,478

5 in stock

Compare

The most important features of CMM-10 are:

  • Autoranging/manual range selection.
  • DATA HOLD function, for holding measured values.
  • REL function, which allows you to make measurements relative to a stored reference value.
  • Continuity test with acoustic signalling (beeper).
  • AUTO-OFF function.
  • Display 3 7/8 digits (5000 max).
Category:
Weight 0.2 kg
Dimensions 14 × 7 × 4 cm

Frequency measurement

Range Resolution Accuracy
5,000 Hz 0,001 Hz ±(1,5% m.v. + 5 digits)
50,00 Hz 0,01 Hz
500,0 Hz 0,1 Hz ±(1,2% m.v. + 3 digits)
5,000 kHz 0,001 kHz
50,00 kHz 0,01 kHz
500,0 kHz 0,1 kHz
5,000 MHz 0,001 MHz ±(1,5% m.v. + 4 digits)
10,00 MHz 0,01 MHz
  • sensitivity: ≥8 V RMS

Duty cycle measurement

Range Resolution Accuracy
0,1…99,9% 0,1% ±(1,2% m.v. + 2 digits)
  • sensitivity: ≥8 V RMS,
  • pulse width: 100µs – 100 ms,
  • frequency width: 5 Hz…150 kHz.

Temperature measurement

Range Resolution Accuracy*
-20°C…+760°C 1°C ±(3% m.v. + 5°C, 9°F)
-4°F…+1400°F 1°F

*) probe (K type) accuracy not included

DC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(0,5% m.v. + 2 digits)
4,000 V 0,001 V ±(1,2% m.v. + 2 digits)
40,00 V 0,01 V ±(1,2% m.v. + 2 digits)
400,0 V 0,1 V
600 V 1 V ±(1,5% m.v. + 2 digits)
  • input impedance: 7,8 MΩ

AC voltage measurement

Range Resolution Accuracy
400,0 mV 0,1 mV ±(1,5% m.v. + 70 digits)
4,000 V 0,001 V ±(1,2% m.v. + 3 digits)
40,00 V 0,01 V ±(1,5% m.v. + 3 digits)
400,0 V 0,1 V
600 V 1 V ±(2,0% m.v. + 4 digits)
  • input impedance: 7,8 MΩ,
  • frequency range: 50…400 Hz.

DC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,0% m.v. + 3 digits)
4 000 μA 1 μA ±(1,5% m.v. + 3 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(2,5% m.v. + 5 digits)
10,00 A 0,01 A

AC current measurement

Range Resolution Accuracy
400,0 μA 0,1 μA ±(1,5% m.v. + 5 digits)
4 000 μA 1 μA ±(1,8% m.v. + 5 digits)
40,00 mA 0,01 mA
400,0 mA 0,1 mA
4,000 A 0,001 A ±(3,0% m.v. + 7 digitgs)
10,00 A 0,01 A
  • frequency range: 50…400 Hz.

Resistance measurement

Range Resolution Accuracy
400,0 Ω 0,1 Ω ±(1,2% m.v. + 4 digits)
4,000 kΩ 0,001 kΩ ±(1,0% m.v. + 2 digits)
40,00 kΩ 0,01 kΩ ±(1,2% m.v. + 2 digits)
400,0 kΩ 0,1 kΩ
4,000 MΩ 0,001 MΩ
40,00 MΩ 0,01 MΩ ±(2,0% m.v. + 3 digits)

Capacitance measurement

Range Resolution Accuracy
40,00 nF 0,01 nF ±(5,0% m.v. + 7 digits)
400,0 nF 0,1 nF ±(3,0% m.v. + 5 digits)
4,000 μF 0,001 μF
40,00 μF 0,01 μF
100,0 μF 0,1 μF ±(5,0% m.v. + 5 digits)

“m.v” = measured value

Electric security:

  • type of insulation: double, according to EN 61010 – 1 and IEC 61557
  • measurement category: CAT II 600 V acc. to EN 61010 – 1:2004
  • protection class acc. to EN 60529: IP40

Other technical data:

  • power supply: 9 V battery type 6LR61
  • diode test: I=0,3 mA, U0 = 1,5 V DC
  • continuity test: I<0,3 mA, sound signal for R<50 Ω
  • over range indication: 0L displayed
  • sampling rate: 2 times per second
  • input impedance: 7,8 MΩ (V AC/DC)
  • display: 5000 counts LCD display with function indication
  • dimensions: 138 x 68 x 37 mm
  • weight: approx. 210 g
  • fuses: mA, µA range: 0,5 A/250 V fast; A range: 10 A/250 V fast
  • auto power OFF: 30 min.
  • accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032

Rated operational conditions:

  • operating temperature: 0…+50°C at <70% rel. humidity
  • storage temperature: -20…+60°C at <80% rel. humidity

Brand

SONEL

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “CMM-10 Multimeter”

There are no reviews yet.

  • UTD2025CL Digital Storage Oscilloscope

    0 out of 5
    (0)

    1. Dual analog channels width range 1mV/div~20V/div;
    2. 7 inches widescreen LCD displays;
    3. Special Print Scree Feature;
    4. Supports plug-and-play USB storage device. Communication with and remote control of computer through the USB device;
    5. USB drive system software upgrade;
    6. Storage of waveforms setups and interfaces waveforms and setups reproduction;
    7. Automatic measurement of 28 waveform parameters;
    8. Unique waveform recording and replay function;
    9. Multilingual menu displays.

    SKU: n/a
  • YH 133A ELEMENT FOR 907A,907C

    0 out of 5
    (0)

    Features Of Soldering Iron Heating Element YH-133A For 907A,907C:

    • Suitable for YIHUA 936, 937D, 878serial, 852 serial, 898D, 898BD, 862D, 8786D, 868D and so on.
    • If the soldering iron is burned, use the heating core to replace the old one.
    • Stainless steel materials.
    • Fast heating.
    • 100% brand new product.
    • Made of high-quality material.
    SKU: n/a
  • UT361 Anemoscopes

    0 out of 5
    (0)

    UT360 series anemograph is a professional anemograph used to measure wind temperature, wind speed and wind capacity, which is of stable performance, reliable and of neoteric appearance. The device can be widely used in the fields such as environmental protection, labor hygiene, industrial enterprise, scientific research. It is applied to environmental noise measurement, machinery equipment noise and architectural acoustics measurement.

    SKU: n/a
  • UT39C+ Digital Multimeter

    0 out of 5
    (0)

    1. 1000V DC voltage measurement

    2. 750V AC voltage measurement
    3. 10A DC/AC current measurement
    4. Resistance/Capacitance
    5. hFE
    6. Diode/Continuity test
    SKU: n/a
  • UT300A+ Infrared Thermometer

    0 out of 5
    (0)

    1. Simple one button operation

    2. 10:1 D:S ratio
    3. Data hold
    4. Backlight
    5. Temperature range: -20℃~400℃
    SKU: n/a