- Insulation resistance measurement:
- selectable measurement voltage in the 100…2500 V range with 100 V step,
- continuous indication of insulation resistance or leakage current,
- automatic discharge of capacitance of tested object after the insulation resistance measurement,
- acoustic signalling of five-second periods to facilitate obtaining time characteristics,
- measured test times T1, T2 i T3 to measure one or two absorption coefficients in 15, 60 and 600 s,
- indication of actual test voltage during the measurement,
- protection against measuring live objects,
- two and three-lead measurement method,
- Continuity measurement of protective and equipotential conductors according to EN 61557-4
- with the >200 mA current.
- Leakage current measurement.
- Measurement of alternating and direct voltages in the 0…750 V range.
- Built-in rechargeable battery pack.
- The instruments meet the requirements of the EN 61557 standard.
- The ability to charge from car lighter (12 V) socket (additional accessories).
MIC-2501,2500V Insulation Resistance Meter
1 in stock
Electrical safety:
- type of insulation: double, in acc. with EN 61010-1 und IEC 61557
- measurement category: IV 600 V (III 1000 V) in acc. to EN 61010-1
- case protection rating in acc. with EN 60529: IP65
Other technical specifications:
- power supply of the meter SONEL L-1 NiMH 9,6 V; DC 12 V 2,5 A
- weight of the meter: approx. 0,9 kg
- dimensions: 200 x 180 x 77 mm
- display: LCD segment display
- measurement results memory: 990 cells, 11880 records,
- transmission of measurement results: USB
₨0
1 in stock
CompareWeight | 0.9 kg |
---|---|
Dimensions | 20 × 18 × 8 cm |
Insulation resistance measurement (two-lead)
Measurement range acc. to IEC 61557-2 for RISOmin=UISOnom/IISOmax…1 TΩ (IISOmax=1 mA)
Range | Resolution | Accuracy |
---|---|---|
0,0…999,9 kΩ | 0,1 kΩ | ±(3% m.v. + 20 digits) |
1,000…9,999 MΩ | 0,001 MΩ | ±(3% m.v. + 20 digits) |
10,00…99,99 MΩ | 0,01 MΩ | ±(3% m.v. + 20 digits) |
100,0…999,9 MΩ | 0,1 MΩ | ±(3% m.v. + 20 digits) |
1,000…9,999 GΩ | 0,001 GΩ | ±(3% m.v. + 20 digits) |
10,00…99,99 GΩ | 0,01 GΩ | ±(3% m.v. + 20 digits) |
100,0…999,9 GΩ | 0,1 GΩ | ±(3% m.v. + 20 digits) |
Values of measured resistance depending on measurement voltage
Voltage UISO | Measurement range |
---|---|
100 V | 50 GΩ |
200…400 V | 100 GΩ |
500…900 V | 250 GΩ |
1000…2400 V | 500 GΩ |
2500 V | 1000 GΩ |
Continuity measurement of protective connections and equipotential bonding with 200 mA current.
Measurement range acc. to EN 61557-4: 0,10…999 Ω
Range | Resolution | Accuracy |
---|---|---|
0,00…19,99 Ω | 0,01 Ω | ±(2% m.v. + 3 digits) |
20,0…199,9 Ω | 0,1 Ω | ±(2% m.v. + 3 digits) |
200…999 Ω | 1 Ω | ±(4% m.v. + 3 digits) |
- Voltage on open terminals: 4…24 V
- Output current at R <2 Ω: ISC >200 mA
- Compensation of test lead resistance
- Current flowing in both directions, mean value of resistance is displayed
DC and AC voltage measurement
Range | Resolution | Accuracy |
---|---|---|
0…299,9 V | 0,1 V | ±(3% m.v. + 2 digits) |
300…750 V | 1 V | ±(3% m.v. + 2 digits) |
- Frequency range: 45…65 Hz
The acronym “m.v.” stands for a “measured reference value”.
Based on 0 reviews
Be the first to review “MIC-2501,2500V Insulation Resistance Meter”
-
Wire & Cable Testers
LKZ-1000 Wires and pipe locator
- Passive or active modes of tracing.
- Detection of underground live wires.
- Detection of underground wires with no voltage (radio mode).
- Detection of underground wires with no voltage using a transmitter (galvanised, inductive or clamp-based connection).
- Tracing metallic or non-conductive pipes using an additional probe.
- Tracing non-conductive pipelines using a “floating” probe.
- Tracing a determined cable.
- Determining the depth of a cable.
SKU: n/a -
DC Power Supplies
YIHUA 605D DC Power Supply
YH-605D communication maintenance power supply
605D communication maintenance power supply is a single line output of stabilized high accuracy
DC stabilized power supply. The output voltage and current can be adjusted continuously within
the rated range. Double digital display shows output voltage and current independently. Several
protection functions include current limitation, voltage reduction, short circuit protection, over-
temperature protection, etc.
The design is applied to production line of the plant, maintenance, laboratories and is also
a necessary device for the communication industry.
SKU: n/a