-29%

Battery Load Tester – BT 100D

Availability:

7 in stock


  • 100 Amp Digital Battery Load Tester
  • Microprocessor Control–makes for an easy and accurate load test with no need to time yourself
  • Bright, LED Digital Display–indicates both voltage and test results
  • Unique 3-Step Design–LED polarity check function, battery load test and charging system test readout
  • Super-Grip Battery Clamps–heavy-duty and color-coded
  • Baked Enamel, Steel Case–ventilated to keep cool
  • Rubber Insulated Carrying Handle–for comfort and safety
  • Checks both Battery and Charging System

5,000 7,000

7 in stock

Compare

The BT-100D 100+ Amp Digital Battery Load Tester is microprocessor controlled. It makes for an easy and accurate load test with no need to time yourself to get accurate results. Bright, LED Digital Display indicates both voltage and test results. A unique 3-Step Design provides LED polarity check function, battery load test and charging system test readout. Automatically Turns Off the Load after 10 seconds and locks the voltage. Super-Grip Battery Clamps are heavy-duty and color-coded. Baked Enamel, Steel Case to keep cool. Rubber Insulated Carrying Handle–for comfort and safety. Checks both Battery and Charging System.

Category: Tag:
Weight 0.7 kg
Dimensions 15 × 8 × 6 cm

12 Volt Battery Analysis

Press “START TEST” & wait for 10 seconds.
Once automatic test cycle is completed, your test results will be:

1.
 GREEN LIGHT = OK):
Battery capacity is good. May or may not be fully charged.
Determine state of charge by checking specific gravity (use hydrometer). If gravity is less than full charge, check for possible charging system trouble or electrical drain. Recharge battery to fully charged level.

2. GREEN + YELLOW LIGHT = OK BUT WEAK):
Review the load test result with the comparison chart on the tester cover to see if this battery is “OK” or not. If it is “OK”, go up to 1ST “OK” state. If it is not, go down to 3rd “WEAK” state.

3. YELLOW LIGHT = WEAK):
Battery capacity is unsatisfactory. Battery may be either: (1) defective or (2) partially discharged. To determine which, check specific gravity. If gravity is over 1.225, battery is considered defective. If gravity is under 1.225, recharge battery and re-test. If cell-to-cell gravity varies more than 0.025 (25 points), cell trouble may exist. If charging does not bring gravity to fully charged level, the battery is either sulfated or has lost active material.

4. RED LIGHT = BAD):
Battery may be defective (e.g. a bad cell).

NOTE: If pre-test battery voltage is below 12.3V, tester will not allow and should not perform the load test. Please fully charge battery and retest.

Brand

TITAN

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Battery Load Tester – BT 100D”

There are no reviews yet.

  • UT681L Cable Tester

    0 out of 5
    (0)

    Main Features

    1. Tests Ethernet cables and telephone lines

    2. Equipped with RJ45 interface for Ethernet cable and RJ11 interface for telephone line testing

    3. Ethernet cables: Shielded/Unshielded test

    4. Visible LED indication

    5. Automatically check circuit breakage, short circuit and cross circuit

    6. Can toggle between fast and slow speed test modes

    7. Single key operation

    8. Manual/auto power off (after 10-minute inactivity)

    9. Low battery indication

    10. Power supplied by 9V layer-built battery

    SKU: n/a
  • UNI-T 2 Channel UPO2102E Ultra Phosphor Oscilloscope

    0 out of 5
    (0)
    • 100MHz bandwidth
    • number of channels 2
    • sampling 1GS / s
    • max memory depth 56Mpts (per channel) (previously 28Mpts per channel)
    • waveforms per second up to 80,000 wfms/s (formerly 50,000 wfms/s)
    • time base range 5ns/div – 50s/div
    • input coupling (1MΩ ± 2%) // (20pF ± 3pF)
    • verical axis 1mV/div – 20V/div (1MΩ)
    • DC gain accuracy ± 3%
    • number of saved waveforms 65000
    • trigger : Edge, Window, Runt, Time Out, Nth Edge, Delay, Duration, Setup / Hold, Pulse Width, Slope, Video, Pattern, RS232 / UART, I2C, SPI
    • mathematical operations with waveforms : A + B, A-B, AxB, A / B, FFT, Logic operation, Editable Advanced, Filter
    • automatic Measurement : Max, Min, High, Low, Middle, Pk-Pk, Ample, Mean, Cycle Mean, RMS, Cycle RMS, Cycle Area, OverShoot, PreShoot, Period, Freq, Rise, Fall, + Width, -Width, + Duty, -Duty, RiseDelay, FallDelay, Phase, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF
    • number of measurements : 5 simultaneous measurements
    • statistics : Mean, Max, Min, standard deviation, number of measurements
    • frequency counter : 6 bits
    • standard interfaces : USB-Host, USB-Device, LAN, AUX (Trig Out, Pass / Fail)
    SKU: n/a
  • MIC-15k1 ,15kV Insulation Quality Analyzer

    0 out of 5
    (0)

     

    Features:

    • Diagnostics of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD, widened with thepartial discharge (PD) indicator for every each of these measurements.
    • It allows testing the electrical durability of the tested object – breakdown voltage indication.
    • High resistance to electromagnetic interferences guarantees uninterrupted work in power stations and close to high voltage transmission lines up to 1200 kV AC and 500 kV DC.
    • The function of smooth voltage rise in time (RT – Ramp Test) allows to state the partial discharges in the facility and to carry out a partial location of their occurrence.
    • Efficient converter with a power of ~150 W that enables insulation burnout, allowing for pinpointing the location of cables and wires short circuit using one of the following:
      • visual method (if power cables are visible along the entire length),
      • reflectometric methods, seismic-acoustic waves detector, or with A-frame to indicate direction of the fault (the conductor must be buried in the ground with earth direct contact).
    • Compatible with external software.
    SKU: n/a