Industrial multimeter CMM-40 was designed for the purpose of measurements of AC/DC voltage, AC/DC current, resistance, capacitance, frequency (electrical and electronic), duty cycle, temperature and also for testing diodes and continuity.
CMM-40 Industrial Multimeter
5 in stock
The most important features of CMM-40 are:
- autoranging/manual range selection,
- „DATA HOLD” function, for holding measured values,
- „REL” function, which allows you to make measurements relative to a stored reference value,
- „MAX/MIN” function,
- „PEAK HOLD” function,
- memory for 2000 measurement resultS,
- continuity test with acoustic signalling (beeper),
- „AUTO-OFF” function,
- display 4¾ digits (40000 max),
- double molded, waterproof casing.
₨30,270 ₨34,221
5 in stock
CompareWeight | 0.4 kg |
---|---|
Dimensions | 19 × 8 × 5 cm |
Frequency measurement (electronic)
Range | Resolution | Accuracy |
40,000 Hz | 0,001 Hz | ±(0,1% m.v. + 1 digit) |
400,00 Hz | 0,01 Hz | |
4,0000 kHz | 0,0001 kHz | |
40,000 kHz | 0,001 kHz | |
400,00 kHz | 0,01 kHz | |
4,0000 MHz | 0,0001 MHz | |
40,000 MHz | 0,001 MHz | |
100,00 MHz | 0,01 MHz | not speccified |
- Sensitivity: 0.8 V rms min. @ 20% to 80% duty cycle and <100 kHz; 5 V rms min @ 20% to 80% duty cycle and > 100 kHz
Frequency measurement (electrical)
Range | Resolution | Accuracy |
40,00 Hz…10,000 kHz | 0,01 Hz…0,001 kHz | ± 0,5% m.v. |
- sensitivity: 1 V rms
Duty cycle measurement
Range | Resolution | Accuracy |
0,10…99,00% | 0,01% | ±(1,2% m.v. + 2 digits) |
- pulse width: 100μs – 100 ms,
- frequency width: 5 Hz…150 kHz.
Temperature measurement
Range | Resolution | Accuracy |
-50,0°C…+1200,0°C | 0,1°C | ±(1% m.v. + 2,5°C) |
-58,0°F…+2192,0°F | 0,1°F | ±(1% m.v. + 4,5°F) |
DC voltage measurement
Range | Resolution | Accuracy |
400,0 mV | 0,01 mV | ±(0,06% m.v. + 4 digits) |
4,0000 V | 0,0001 V | |
40,000 V | 0,001 V | |
400,00 V | 0,01 V | |
1000,0 V | 0,1 V | ±(0,1% w.m. + 5 cyfr) |
AC voltage measurement (True RMS)
Range | Resolution | Accuracy |
400,00 mV | 0,01 mV | ±(1% m.v. + 40 digits) |
4,0000 V | 0,0001 V | ±(1% m.v. + 30 digits) |
40,000 V | 0,001 V | |
400,00 V | 0,01 V | |
1000,0 V | 0,1 V |
- frequency range: 50…1000 Hz.
AC/DC current measurement (True RMS)
Range | Resolution | Accuracy |
400,00 μA | 0,01 μA | dla DC ±(1,0% m.v. + 3 digits)
dla AC ±(1,5% m.v. + 30 digits) |
4 000,0 μA | 0,1 μA | |
40,000 mA | 0,001 mA | |
400,00 mA | 0,01 mA | |
10,000 A | 0,001 A |
- 20 A: 30 sec max with reduced accuracy.
Resistance measurement
Range | Resolution | Accuracy |
400,00 Ω | 0,01 Ω | ±(0,3% m.v. + 9 digits) |
4,0000 kΩ | 0,0001 kΩ | ±(0,3% m.v. + 4 digits) |
40,000 kΩ | 0,001 kΩ | |
400,00 kΩ | 0,01 kΩ | |
4,0000 MΩ | 0,0001 MΩ | |
40,000 MΩ | 0,001 MΩ | ±(2,0% m.v. + 10 digits) |
Capacitance measurement
Range | Resolution | Accuracy |
40,000 nF | 0,001 nF | ±(3,5% m.v. + 40 digits) |
400,00 nF | 0,01 nF | |
4,0000 μF | 0,0001 μF | ±(3,5% m.v. + 10 digits) |
40,000 μF | 0,001 μF | |
400,00 μF | 0,01 μF | |
4000,0 μF | 0,1 μF | ±(5% m.v. + 10 digits) |
40,000 mF | 0,001 mF |
Other technical data:
- power supply: 9 V battery type 6LR61
- diode test: I=0,9 mA, U0 = 2,8 V DC
- continuity test: I<0,35 mA, sound signal for R<35 Ω
- over range indication: 0L displayed
- crest factor: ≤ 3 at full scale up to 500 V; decreasing linearly to ≤ 1,5 at 1000 V
- PEAK: captures peaks >1 ms
- sampling rate: 2 times per second
- input impedance: 10 MΩ (V DC), 9 MΩ (V AC)
- display: 40000 counts backlit LCD with bargraph, 4¾ digits
- store capacitance: 2000
- dimensions: 187 x 81 x 55 mm
- weight: 342 g
- fuses: mA, µA range: 0,5 A/1000 V ceramic fast blow; A range: 10 A/1000 V ceramic fast blow
- auto power OFF: 15 min.
- accordance with following standards: EN 61010 – 1:2004, EN 61010 – 2 – 032
Electric security:
- type of insulation: double, according to EN 61010 – 1 and IEC 61557
- measurement category: CAT III 1000 V acc. to EN 61010 – 1:2004
- protection class acc. to EN 60529: IP67
Rated operational conditions:
- operating temperature: 0…+40°C
- storage temperature: -20…+60°C
- operating humidity: max 80% up to 87°F (31°C); decreasing linearly to 50% at 104°F (40°C)
- operating altitude: max 2000 m
„m.v.”- measured value
Based on 0 reviews
Be the first to review “CMM-40 Industrial Multimeter”
-
Environment Meters
UT337A Carbon Monoxide Meter
UT337A is a portable carbon monoxide meter with wide detection range, short response time, long term stability, and long service life. It provides many functions such as CO concentration display, maximum value, average value, audible and visual alarm, temperature display, etc. It is suitable for carbon monoxide detection in residential homes, restaurants, indoor parking lots and gas heating facilities.
Features:
1. High-sensitivity electrochemical sensor
2. Light and sound alarm
3. Sensor self-check
4. Battery powered, 20 minutes automatic power off
5. Portable
6. The alarm value of CO can be set
7. Maximum value
8. Temperature
9. LCD backlight
SKU: n/a -
-
Clamp Meters
CLAMP METER AC BM 5268
BM5268 AC Digital Clamp meter Technical parameters Functions Range Accuracy BM5268 DC Voltage 400mV/4V/40V/400V/600V ±(0.8%+2) AC Voltage 4/40/400/600V ±(1.2%+5) AC Current 4/40/400/600A ±(2%+10) Ω Resistance 400/4K/40K/400K/4M/40MΩ ±(1%+3) Capacitance 10n/100n/1μ/10μ/100μ/1m/10mF ±(3%+5) Frequency 10/100/1K/10K/100K/1M/30MHz ±(0.5%+3) ºC/ºF -50ºC~1000ºC ±(1%+5) -58ºF~1832ºF ±(1.2%+6) Functions Range Accuracy True RMS √ Manual range √ Automatic range √ Auto power OFF About 10minutes √ Auto power OFF/Manually turn it off √ Diode Test √ VHZ voltage measuring frequency √ Phase line recognition √ Continuity Testing √ Data hold √ INR Surge voltage √ low Battery indication √ Overload protection √ Greatest display 1999 √ Jaw Size Φ30mm General Features Power DC9V(6F22)Battery Color Gray+Red Weight About 220g Size 195×64×35mm Standard accessories Multimeter leads+Batteries+Temperature Sensor Standard Pack Color Box,User Manua Safety rating EN61010-1,CAT.II 600V SKU: n/a -
Oscilloscopes
UNI-T MSO3154E 150MHz Mixed Signal 4 Channel Digital Oscilloscope
Analog bandwidth 150MHz 250MHz Channels 2+16 digital 4+16 digital 2+16 digital 4+ 16digital Sampling rate (Analog) 2.5GS/s (Single channel), 1.25GS/s (Dual channels) Sampling rate (Digital) 1.25GS/s (Eight channels), 625MS/s(Sixteen channels) Memory depth 70Mpts Waveform capture rate 200,000wfms/s Time base scale 2ns/div~50s/div (Real-time sampling rate, memory depth display ) Time base scale (digital) 2ns/div~40S/div[Step by 1-2-4 stall] Input impedance (1MΩ±1%) II (20pF±3pF) Input impedance digital (101kΩ±1%) II (9pF±1pF) Vertical scale 1mV/div~20 V/div (1 MΩ) DC gain accuracy <5mV: ±3%, ≥5mV: ±2% Waveform record 100,000 frames Trigger types Edge, Runt, Window, Nth Edge, Delay, Overtime, Duration, Setup/Hold, Pulse Width, Slop, Video, Code; RS232/UART, I2C, SPI, USB,
CAN, LIN, FlexRayBus decode RS232/UART, I2C, SPI, USB, CAN, LIN, FlexRay Waveform operations A+B, A-B, A×B, A/B, FFT, editable advanced and logical operations Auto measurements
Max, Min, High, Low, Ampl, Pk-Pk, Middle, Mean, CycMean, RMS, CycRMS, Period, Freq, Rise, Fall, RiseDelay, FallDelay, +Width,
-Width, FRR, FRF, FFR, FFF, LRF, LRR, LFR, LFF, +Duty, -Duty, Area, CycArea, OverSht, PreSht, Phase, 34 parameters in totaldigital
channel: Freq, Period, +Width, -Width, +Duty, -Duty, RiseDelay A→B,FallDelay A→B, Phase A→B, Phase B→AMeasurement display 5 types Measurement statistics Average, Max, Min, standard deviation and number of measurements Frequency counter 6 bits Standard interfaces USB Host, USB Device, LAN, EXT Trig, AUX Out (Trig Out, Pass/Fail), AWG,UT-M15 logic analyzer probe, VGA Standard Accessories
USB interface cable UT-D14 Passive Probe x 2/4 (1 x , 10 x switchable,300MHz,) UT-P06 Passive Probe x 2/4 (1 x , 10 x switchable,200MHz,) UT-P05 16CH Logic analyzer probe UT-15M SKU: n/a
There are no reviews yet.